Why SECS/GEM Integration Often Proves More Challenging Than Expected

 An equipment manufacturer from a different industry is delivering a machine to a modern semiconductor fab for the first time. Although integration with the fab’s higher-level systems was planned from the outset, the technical and organizational effort required was significantly underestimated. While the mechanical components and control systems were optimized over a period of months and all in-house tests were successful, communication with the host system did not become a priority until shortly before delivery. It is now becoming clear that it is not enough for the equipment to operate reliably. It must also be able to integrate fully and error-free into the fab’s automated processes.

Ultimately, the key issue is that the equipment must be able to interact with the operator’s Manufacturing Execution System (MES). The host system serves as the necessary link for this, mediating between the equipment and the fab’s higher-level production processes.

This is precisely where the real problem begins for many manufacturers. While their equipment knows its own logic inside and out, SECS/GEM requires something different. The equipment must report its status, provide relevant data, and accurately process external commands. 
 

 

The problem runs deeper than it seems

Most systems have evolved over the years, and it shows. Those who operate them have grown accustomed to their quirks, which have developed over time. Some communicate via OPC or OPC UA, while others use proprietary solutions because these were well-suited to the respective requirements at the time of development.

This isn’t particularly noticeable during day-to-day operations. However, as soon as the system is to be integrated into a semiconductor manufacturing facility, this accumulated diversity becomes a real obstacle.

On top of that, the system must be fully understood before even a single line of code for SECS/GEM is written. Which states are relevant for the host and, consequently, for the MES? What information does the customer need to control and monitor their processes and ensure quality?

Those who address this structure too late in the project pay the price. Changes that initially seem minor then ripple through multiple software areas simultaneously, coordination with the customer takes longer than planned, and what was intended to be a brief compliance review becomes a real test of patience.
 

 

The standard alone does not solve the problem

At this point, the obvious question arises as to whether the existing standards do not already provide a clear solution. SECS, HSMS, and GEM have long been established in the semiconductor industry. Put simply, SECS and HSMS govern the exchange of data between the equipment and the host, while GEM specifies how the equipment is to behave in this process. The host system then links the relevant information and commands to the overarching processes of the MES.

That sounds like a clear guideline, and it is. However, the standard does not solve the actual problem—namely, implementation for the specific machine right in front of you. A front-end machine, for example, requires something completely different from a back-end machine. And if the customer also requests GEM300, that adds yet another unique set of considerations.

Anyone who has already managed several such projects no longer falls into the same traps at these points. They know from experience which decisions will pay off later and which will eventually become maintenance issues. It is precisely this experience that many manufacturers lack when working with SECS/GEM for the first time. 
 

 

The first step toward a solution: a clear structure

A SECS/GEM integration that works reliably in everyday use starts at the desk with a clear description of what the system is actually capable of and what it is supposed to do. Only once this description is in place does it make any sense to begin programming.

This process doesn’t just define what data the system provides. It also specifies what information the MES needs from the host, which commands must be processed, and how the system should respond in different situations.

This groundwork pays off for everyone involved. The developer knows exactly what to build, rather than having to constantly ask for clarification during implementation. And the customer can understand in advance how their system will actually communicate with the host later on, rather than finding out only at the end.

We therefore maintain the relevant system data in Excel and document it in a way that anyone can understand. This creates a foundation that can be coordinated with the client and expanded as needed without anything falling through the cracks. We then automatically generate the source code for the software project from this description. On the one hand, this saves time during implementation; on the other hand, and most importantly, it ensures that future changes are incorporated in a controlled manner, rather than having to be manually updated in ten different places in the code.
 

 

The EQS SECS Driver as a Practical Solution

With the EQS SECS driver, we support equipment manufacturers precisely in this area. The driver already includes the core SECS/GEM functions and can be integrated into existing equipment software without having to start from scratch. Events, alarms, and variables are managed in a structured manner and are transferred directly into the .NET project via the code generator.

For the manufacturer, this ultimately means an interface that remains clear and is easy to maintain, without recurring tasks requiring new effort each time. Because the driver is based on Microsoft’s .NET, it also integrates seamlessly into most existing software environments without requiring a redesign of the system architecture.
 

 

And what about systems that are already in use?

Not every project starts from scratch. Many machines have long been in operation somewhere on the production floor, built at a time when no one had even considered integrating them into modern manufacturing environments. Nevertheless, it is precisely these machines that now need to be integrated without having to completely rebuild them.

For such cases, there’s the optional Matrix Gateway. It acts as a translator between the SECS world and the communication protocol the system has used up to now—whether that’s OPC, OPC UA, or a proprietary interface. This way, the machine’s proven functionality remains intact while it’s made ready to meet new requirements. In retrofit projects, this is often the deciding factor in whether a system has to be decommissioned or can continue running for many more years.
 

 

Conclusion

SECS/GEM deserves genuine attention from the very beginning, not just shortly before the project ends. The technology is a central component of modern semiconductor manufacturing because it enables standardized communication between the equipment and the host.

However, its true purpose goes beyond that. The equipment is integrated into the MES processes via the host system. Only then can it fully participate in the fab’s automated production control, process monitoring, and quality assurance.

Integration is most successful when standard knowledge and equipment expertise are combined from the very beginning, rather than only when the project is already under tight deadlines.

In addition to SECS, HSMS, GEM, and GEM300, we also support other SEMI standards from the E Series, M Series, MF Series, T Series, and A Series. This allows us to tailor the integration specifically to the requirements of the respective equipment, process, and manufacturing environment.
 

 

Interested?

If you are currently facing a similar challenge or are looking for support with implementation, please feel free to contact us.

We will take the time to address your concerns, provide personalized advice, and look forward to working with you to find a suitable solution.

PROJECT CONSULTING & SALES

Would you like to improve processes, develop software or start a digitalization project? We listen, help clarify your needs and bring the right specialists together.

Call us now

WHERE DO YOU STAND RIGHT NOW?

Sometimes a single conversation is enough to gain clarity. Tell us about your situation and you'll get an honest assessment, no sales pitch.

If it's a good fit, we'll bring in the right people for your topic. Real experts.

 

To contact form

HOW WE WORK

A compact insight into our approach, typical projects and the areas where we most often support companies today. Download it now!

Download Brochure

Speak to us +49 941 2984477-0